Specially designed for decoratice coating,SINOARC ion plating equipment is an innovative arc ion plating system.Its bias power is an essential product developed for tools coating which powerfully increase plasma energy and effectively improves film hardness and adherence.
Features
1.Vacuum Chamber
The chamber of which cover can be disassemble and has a workpiece jig on it ,has a front door on chamber for loading and unloading workpieces, one peep hole located on the door.There are several flange holes on side chamber used to install tagets. The chamber body and front door are whole water jacket structured and made of stainless steel.There ,besides , is a square-shaped flange hole for connection to vacuum system. Under the bottom, one hole for installation of heater, two for gas supply ,one stainless neck bush for keeping chamber clean featured with easily disassemble and convenient for regular clean.chamber is placed on a tank which contains gas supply system, side water cooling system, cables of system control and power supply. The tank is made of carbon steel and painted with anti-corrosive paint.
Chamber Detail
| Mode |
SA-1015-M6-DP |
SA-1015-A8M2-DP |
SA-1212-A8-DP |
SA-1212-A10-DP?? |
SA-1215-A16-DP |
SA-1512-M10-DP |
SA-1830-A26-DP |
SA-1315-A16-DP??? |
| Inner diameter |
1000mm |
1000mm |
1200mm |
1200mm |
1200mm |
1500mm |
1800mm |
1200mm |
| Height |
1500mm |
1500mm |
1200mm |
1200mm |
2500mm |
1200mm |
3000mm |
1500mm |
| Targets |
6 pcs sput targets |
8 pcs arc targets & 2 pcs sput targets |
8 pcs arc targets |
10 pcs arc targets |
16 pcs arc targets |
10 pcs sput targets |
26 pcs arc targets |
16 pcs arc targets |
2.Vacuum System
Many techniques have been developed for the measurement of pressure and vaccum. In addition to pumps, the system also has valves,connecting pipes,cryotrapping and instruments used to measure pressure which is a thermocouple and ionization combined vaccum gauge.Hence, by combining several different types of gauge, it is possible to measure system pressure continuously from 103pa down to 10-4 pa.
Following devices are consisted to achieve requirement of pump down.
| SA-1015-M6-DP |
-
Rotary vane vacuum pump 2X-30 1 set
-
Rotary vane vacuum pump 2X-70 1 set
-
Oil diffusion pump(ODP) k400T 1 set
-
Roots pump ZJ-150 1 set
|
| SA-1015-A8M2-DP |
-
Rotary vane vacuum pump 2X-30 1 set
-
Rotary vane vacuum pump 2X-70 1 set
-
Oil diffusion pump(ODP) k500T 1 set
-
Roots pump ZJ-150 1 set
|
| SA-1212-A8-DP |
-
Rotary vane vacuum pump 2X-30 1 set
-
Rotary vane vacuum pump 2X-70 1 set
-
Oil diffusion pump(ODP) k-600T 1 set
-
Roots pump ZJ-300 1 set
|
| SA-1212-A8-DP |
-
Rotary vane vacuum pump 2X-30 1 set
-
Rotary vane vacuum pump 2X-70 1 set
-
Oil diffusion pump(ODP) k400T 1 set
-
Roots pump ZJ-150 1 set
|
| SA-1215-A16-DP |
-
Rotary vane vacuum pump 2X-30 1 set
-
Rotary vane vacuum pump 2X-70 1 set
-
Oil diffusion pump(ODP) k400T 1 set
-
Roots pump ZJ-150 1 set
|
| SA-1315-A16-DP |
-
Rotary vane vacuum pump 2X-30 1 set
-
Rotary vane vacuum pump 2X-70 1 set
-
Oil diffusion pump(ODP) k400T 1 set
-
Roots pump ZJ-150 1 set
|
| SA-1830-A26-DP |
-
Rotary vane vacuum pump 2X-30 1 set
-
Rotary vane vacuum pump 2X-70 1 set
-
Oil diffusion pump(ODP) k400T 1 set
-
Roots pump ZJ-150 1 set
|
| SA-1512-M10-DP |
-
Rotary vane vacuum pump 2X-30 1 set
-
Rotary vane vacuum pump 2X-70 1 set
-
Oil diffusion pump(ODP) k-500T 1 set
-
Roots pump ZJ-150 1 set
|
-
Features:
pump down time from 105Pa down to 6.6X10-3Pa less than 20 min.
cool condition, no loading Ultra-high vaccum down to 1.3X10-3Pa.
Example reading: 1 Pa = 1 N/m2 = 10−5 bar = 10.197×10−6 at = 9.8692×10−6 atm = 7.5006×10−3 torr = 145.04×10−6 psi
etc.
3. Gas supply system
Two or three kinds of gases can be injected the system for plating. Each inject has necessary stop valve and flow controller. Flow ranges from 0 up to 500 sccm.
-
automatic chamber pressure track
-
automatic adjustment of inject
-
flow mass display of each inject gas
-
no need for gas mixing cylinder, no adjustment delay
-
capable of autometic or manual preset of mass proportion
4. Heating System
The system has a tube-shaped heater and connected power. The heater ,digital readout controlled, continuously adjustable ,has able to exactly control the temperature.
power detai
| Mode |
SA-1015-M6-DP |
SA-1015-A8M2-DP |
SA-1212-A8-DP |
SA-1212-A10-DP?? |
SA-1215-A16-DP |
SA-1512-M10-DP |
SA-1830-A26-DP |
SA-1315-A16-DP??? |
| power |
|
|
|
|
|
|
|
|
5. Temperature measurement
Measurement is fulfilled by thermocouple ,with sensor(thermosistor) placed inside vacuum chamber. It can sense environment temperature of chamber. For determining surface temperature of workpiece, IR(infrared) thermosistor is optional.
6. Workpiece Jig
Workpiece jig is fixed under chamber cover. It can revolve at speed 4r/min and rotate at 15r/min. There are 6 or 8(outter round) single-rotating hangers.
Rotating speed of jig is frequency conversion controlled and continuously adjustable.
The jig can start-up smoothly.
| Mode |
SA-1015-M6-DP |
SA-1015-A8M2-DP |
SA-1212-A8-DP |
SA-1212-A10-DP?? |
SA-1215-A16-DP |
SA-1512-M10-DP |
SA-1830-A26-DP |
SA-1315-A16-DP??? |
| loading capacity |
|
|
|
|
|
|
|
|
7.Evaporator and its power supply
6 sets of arc evaporator with automatic discharge devices, source target sized(100mmX40mm) 3 sets of power supplier for 6 evaporators.
-
built-in electric field
-
horizontal magnetic field of constant strength
-
direct water cooling(or undirect water cooling)
-
automatic discharge
-
quick arc connecting function
-
special arc maintenance circuit
8.Bias Power
This power supply is a powerful DC supply specially designed for tools coating. It has special protective circuit and arc extinction system.
-
7.5KW for each target highly increases plasma energy to obtain .high qualitied tools coating film. In case of full loading with 6 targets burning , coating can carry on easily at bombardment voltage 1000V.
-
eliminite arcs completely
-
digital readout control
-
voltage modulation of arc bombardment provides high field energy
-
quick recover function available
9. Control System
There are two control systems for customer's choice: semi-automatic control or automatic control.
9.1 Semi-automatic control system consists of a relay matrix or a PLC system which has following function:
-
preheating preset, machine on at specialized temperature
-
automatic delay, machine off at specialized temperature
-
frequencey converted speed adjustment
-
automatic pumping down
-
ODP temperature controlled at certain temperature, optimised ODP function and minimized return oil rate
-
automatic tune to preset of BPS
-
automatic evaporator failure indication
9.2 Automatic control system
The whole coating process is controlled by computer system.
Functions: system monitor, system diagnosis and coating process management.
10. Working condition
10.1 Total power: 90KVA, 380V; maxium actual power: 70KVA
10.2 Environment :
-
Total floor: 5m X 6m
- temperature from 10( 50ºF) up to 30
º C( 86ºF)
-
humidity below 80%
-
compressed air: (5-7)?á105Pa(5-7kg/cm ²), air filter available
-
independent ground line: ground connecting resistance below 5W
10.3 Net weight: 2 tons
10.4 Cooling water: 2 tons/hr, inlet temperature below 25
º C( 77 ºF), pressure 2kg/cm ² .
|